Use the image viewer
Open a study in the image viewer, use its tools and command menu, and save and apply your own hanging protocols and layouts.


What this page is for
The image viewer shows a study's images. It opens in its own tab or window, apart from the rest of PacsPilot, and is always dark. Here you scroll, window, zoom and measure images, change the layout, and save hanging protocols that arrange matching studies for you.
The strip along the bottom shows the viewer's intended use. On a phone it starts with "Not for diagnostic use on this device."
Who can use it
Anyone who can see a study on the Worklist can open it in the viewer. Some tools need a role or a practice feature:
- Send to report on a measurement needs a role that can write reports, and the reading cockpit's measurements feature.
- AI shows when the study has AI results or AI jobs.
- Advanced (MPR, 3D, MIP), Lesions and Label spine show only when your practice has those features on. Advanced is not offered on phones.
Your hanging protocols, mouse buttons and keyboard shortcuts are saved to your account, so they follow you to every device you sign in on.
How to open a study
- On the worklist, select the study and press Open, press Enter, or double-click the row. Open stays greyed out until at least part of the study is prepared for viewing.
- To open a prior beside the current study, press Compare next to the prior in the inspector, or under Earlier studies in the viewer's series rail.
- From a report, press Open images.
While the viewer starts, it already loads your access, its settings and the first series' details in the background, so the first image appears as soon as the viewer is ready.
The Viewer window button on the worklist sets whether studies open in a new tab for each study or in one separate window. To go back, press ‹ at the top left of the viewer. It returns to the worklist tab that opened the viewer when that tab is still open; otherwise it opens the worklist in this tab.
How to use the dock, Tools and the command menu
On a computer or an iPad the viewer has a bar along the top and a dock of tools at the bottom:
- The top bar shows the patient's whole name with sex, age and MRN under it, then the study with its date, modality and accession (on an iPad held upright the study moves into the details). Click the patient or the study for every detail, with Copy MRN. ‹ goes back to the worklist. The magnifier (Search tools and commands) opens the command menu. Then come Undo, Redo, Report and Share when you have them, and ⋯ More, with DICOM tags, Capture, focus mode, full screen and Viewer settings.
- The dock has Scroll, Contrast, Zoom, Pan, Measure, Annotate, Layout, MPR (when your practice has Advanced on), Reset and Tools. The tool you pick is what the left mouse button, or one finger, does on the image. Point at a button to see its keyboard shortcut.
- Tools opens every tool, grouped into View, Measure, your specialty packs and Study, with each tool's shortcut. Type to find one and press it to use it. Buttons other help pages call toolbar buttons, such as Heart size or Draft findings, are here under your specialty packs.
- To change the dock, open Tools, then right-click a tool (or touch and hold it on an iPad) and pick the dock button it replaces. Your dock follows you to every computer you sign in on; iPads keep a dock of their own.
- The series rail on the left lists this study's series as pictures with the series name and image count. The series in the active viewport has a blue ring; with several viewports, each picture shows the number of the viewport it is in. Click a picture to show that series in the active viewport, or drag it onto any viewport. Earlier studies follow, each with Compare. Press [ or the arrow at the bottom of the rail to fold it to a thin edge and back. On an iPad held upright, and in narrower windows, the series sit in a row above the dock instead, with earlier studies after a line.
- Each viewport shows a small bar when you point at it (on an iPad, when you tap it): the series name, Linked while you compare two studies (press it to link them again at the images on screen), Cine for loops, Maximize (or double-click the image) and ⋯ with Reset view, Rotate, Flip, Invert, Orientation, Data overlay, Window level and Overlay text. Overlay text is simple by default, leaving the study date to the top bar; choose full to see every corner. With several viewports, the active one has a blue ring. Drag the slider on the right edge of a viewport to scroll; the image number shows beside the pointer.
- Focus mode hides the bars so the images fill the window: press F, choose it in ⋯ More, or on an iPad tap the image once. Press F, Esc or Exit focus to bring the bars back. Shift+F also makes the browser full screen. The intended-use strip always stays.
- Keyboard shortcuts: press ? (or Ctrl+/, ⌘/ on a Mac), or choose Keyboard shortcuts in ⋯ More, to see every key the viewer answers to, grouped like Tools, with the keys for the layout and the contrast row. Press ? or Esc to close it. Change shortcuts opens Viewer settings, where you set your own.
On a phone the viewer has its own layout, described in Use PacsPilot on phones, tablets and foldables.
- Pick a tool on the dock, or in Tools.
- Press the magnifier in the top bar (Search tools and commands), or press Ctrl+K (⌘K on a Mac), to open the command menu. Type to find a command, then choose it. "No matching command" means nothing fits what you typed.
- Right-click a measurement for Delete measurement, Add Label and, when you can, Send to report.
The command menu lists your hanging protocols, the layouts, Mouse buttons…, Keyboard shortcuts…, the viewer's tools and shortcuts, and the extra tools your practice has on. It also has Next study in worklist (Shift+Page Down) and Previous study in worklist (Shift+Page Up), which work while the worklist that opened the viewer is still open.
How to set contrast and measure on a computer or iPad
- Contrast on the dock shows the window presets for the modality in a row above the dock, each with its number key. Press a preset, or its number (1 to 9), to use it. Drag on the image to change the window by hand; the values show at the top of the image. Double-click the image (double-tap on an iPad) to put the image's own window back. Invert (I) and Auto (A) are at the end of the row. Press Contrast again to close the row.
- Save as preset keeps the window you have now under a name you type, for this modality, after the practice's presets. Your own presets stay in this browser.
- Measure on the dock shows a row of measuring tools: Length, Angle, Cobb, Ellipse, Rectangle, Freehand, Point, Arrow, Calibrate and Region contrast. Above it are the selected measurement's value, with Add to report when you write reports, and Undo, Redo, Delete and Done. Press Done, Esc or Measure again to finish. In a narrow window the tools show as icons; point at one to see its name.
- The magnifier follows your finger or Apple Pencil while you draw or move a handle. With a mouse, hold Alt to see it. On an iPad that supports Apple Pencil hover, it also shows while the Pencil hovers over the image.
- Apple Pencil and fingers. Once you use Apple Pencil, the Pencil draws and your fingers move around: one finger scrolls through the images and two fingers zoom and pan, whatever tool is on. Without a Pencil, your finger draws as before.
- Two-finger tap undoes and three-finger tap redoes on an iPad.
How to use the side panel
On a computer or an iPad, Measure, Report, AI (AI findings), Chat, Key images and Info are tabs of one side panel on the right, each with an icon. Tabs your practice does not have are left out. A number on a tab counts its measurements, unread messages or key images.
- Measure lists the measurements grouped by series, each with its value, where it is, Go to, Add to report (when you write reports) and Delete. Add all to report sends them all. Open segmentation opens the segmentation panel.
- Report shows the report beside the images, with its toolbar at the top and Sign at the bottom. Report in the top bar opens and closes it.
- AI shows the AI results with Accept and Reject, instead of a panel over the images.
- Chat is the study's case chat.
- Key images shows the marked images as pictures. Mark this image marks the image on screen, a picture shows that image, Save to study saves the set.
- Info shows the patient (with Copy MRN), the study, the equipment and the series, with DICOM tags and Copy all.
The ⋯ button at the top of the panel has Open report in new window and Hide side panel.
On a computer, or an iPad held sideways, the panel sits beside the images: drag its left edge to make it wider or narrower. On an iPad held upright, or a narrow window, it opens over the images and a tap on the images tucks it away. Press ] to show or hide it, or choose Side panel in Tools.
DICOM tags
DICOM tags (in ⋯ More, Tools or the Info tab) shows every tag of the image you are looking at. Pick another series at the top, and step through its images with the arrows or the slider (or ← and → on a keyboard). Tags are grouped into sections such as Patient, Identification, Acquisition and Image; the buttons above the list jump to one. Type in the search box to find a tag by number, keyword or value; press / to get there from the keyboard. Sequences fold open and closed. Click or tap a tag to copy its value, or Copy all to copy every tag (or every match) as text for a spreadsheet. On a phone each tag takes two lines so long values wrap.
Extra viewer features
When your practice has them on in Settings › Viewer, the command menu also offers:
- Compare with prior (Shift+C): the best prior opens beside the study, with scrolling, window level and zoom in step.
- Send this view (copy link): copies a link that opens this study at the same view for another member who can see it. Reopening a study also returns to where you left it.
- Open second screen (Shift+M): a second viewer window for your other monitor.
- Key image (mark or unmark) (Shift+K), Save key images… and Show key images.
- Orientation marker, Scale bar, Ultrasound mode, 4D mode, segmentation tools and Start live session, as Viewer features describes.
Animal orientation labels
Images of animals use veterinary direction words instead of head, foot, anterior and posterior. This applies when the image is tagged as a quadruped, or when your practice kind is Veterinary and the image is not tagged as a human (biped). The labels are the DICOM abbreviations:
| Label | Means |
|---|---|
| CR, CD | Cranial, caudal |
| R | Rostral (on the head) |
| D, V | Dorsal, ventral |
| LE, RT | Left, right |
| PR, DI | Proximal, distal (limbs) |
| PA, PL | Palmar, plantar |
The word depends on the body part in the image: rostral on the head, proximal and distal along a limb, palmar on a front paw and plantar on a hind paw. When the image does not say which limb, the label reads PA/PL. X-rays without a stored plane use the image's own orientation, and the labels follow when you rotate or flip it.
A Quadruped badge at the bottom of the image shows whenever these labels are in use, with the positioning view when the image has one (for example Quadruped · Right lateral). If the badge shows on an image of a person, the image is in a veterinary practice without a human tag; check the labels before reading.
Animal hanging protocols
Animal radiographs (DX and CR) open in a layout for their body region, with each view in its own place:
| Body region | Layout |
|---|---|
| Thorax | Right lateral, left lateral, VD (or DV) |
| Abdomen | Lateral, VD (or DV) |
| Pelvis and hips | Extended VD, lateral |
| Stifle, elbow | Lateral, craniocaudal |
| Spine | Lateral, VD (or DV) |
| Skull and dental | Lateral, VD (or DV), oblique, next series |
| Equine distal limb (horses) | Lateromedial, dorsopalmar or dorsoplantar, DLPMO, DMPLO |
The view comes from the image's view position, its view code, or words in the series description such as R LAT, VD or DLPMO. If a view is missing, its place shows the next series. In a veterinary practice, the command menu lists these layouts under Hanging protocols so you can apply one by hand. A protocol you save yourself always wins over these.
Ultrasound and stress echo hanging protocols
Ultrasound studies open in a layout for their exam, picked from words in the study description:
| Exam | Layout |
|---|---|
| Abdomen (liver, kidneys, gallbladder, pelvis) | Four places, each showing the next series |
| Thyroid and neck | Two places side by side |
| Vascular and Doppler (carotid, venous, DVT) | Four places, each showing the next series |
| Obstetric | Four places, each showing the next series |
| Echocardiogram | PLAX, PSAX, apical four chamber, apical two chamber |
| Stress echo | Each view's rest clip beside its stress clip, four views |
An echo view comes from the clip's view name or words in the series description such as PLAX, AP4 or apical 2 chamber. A stress echo is recognised from the stage names the cart records (rest, then later stages); the stress place shows peak stress when there is one, otherwise the next stage after rest. If a view or stage is missing, its place stays empty rather than showing the wrong clip. Press Sync cine to play the clips together. A protocol you save yourself always wins over these.
Trauma hanging protocols
Trauma studies open in a trauma layout, picked from words in the study description:
| Study | Layout |
|---|---|
| CT described as trauma, pan-scan, WBCT or polytrauma | Head, sagittal C-spine, lung, body soft tissue, then coronal and sagittal reformats (2 × 3) |
| Radiographs described as trauma | Chest, pelvis and C-spine side by side |
Each place takes the series whose description names that part, such as Head, C-Spine or Lung. If a part is missing, its place shows the next series. A protocol you save yourself always wins over these.
How to change the layout
- Open the command menu (Ctrl+K).
- Choose a grid: 1 × 1 grid, 1 × 2 grid, 2 × 1 grid, 2 × 2 grid, 2 × 3 grid or 3 × 3 grid.
On a computer or an iPad you can also press Layout on the dock. It opens the grids from 1 × 1 to 3 × 3, the hanging protocols that fit this study (the one in use is ticked and named at the top), and MPR and Compare with prior when your practice has them.
How to save a hanging protocol
- Arrange the layout and put a series in each viewport you want.
- Open the command menu and choose Save layout as hanging protocol….
- Enter a Name. The dialog lists what each cell will look for, and which studies the protocol opens for automatically.
- To limit it further, tick Only for studies whose description contains and enter the text to match.
- Press Save. "It opens automatically for matching studies." confirms it.
A cell that shows a different study from the one you opened is saved as a prior cell. You keep up to 50 saved protocols; saving more drops the oldest.
How to apply a hanging protocol
- Open the command menu.
- Choose Apply: followed by the protocol's name. Your own protocols and the built-in ones are listed, such as MR brain: T1, T2, FLAIR, diffusion, CT chest: soft tissue and lung and Mammography: 4 views.
You can also choose My hanging protocols… and press Apply next to one of yours.
How to delete a hanging protocol
- Open the command menu and choose My hanging protocols….
- Press Delete next to the protocol.
- The row asks "Delete "name"? This cannot be undone." Press Delete to confirm, or Cancel to keep it.
The protocol leaves the list only once the delete is saved.
How to set your mouse buttons
- Open the command menu and choose Mouse buttons….
- Pick what Left button (no tool selected), Right button, Middle button and Wheel do: Window/level, Pan, Zoom, Scroll through images or Nothing.
- Press Save, or Reset to go back to the defaults.
Keyboard shortcuts… opens Viewer preferences (also under ⋯ More, Viewer settings, Preferences), where you pick the viewer's language and change its shortcuts. Click or tap a shortcut's key, then press the new key or keys, and press Save. On a phone the shortcuts are listed only once you have typed on a keyboard connected to it.
Fields and columns
| Name | What it means |
|---|---|
| ‹ | Back to the worklist (top left). |
| Search tools and commands | Opens the command menu (Ctrl+K). Not shown on phones. |
| AI | Shows the study's AI results. |
| Advanced | MPR, 3D and MIP, when your practice has them on. |
| Lesions | The lesion panel (RECIST 1.1), when your practice tracks lesions. |
| Label spine | Label vertebral bodies; levels follow by count. |
| Name | The hanging protocol's name, up to 64 characters. |
| Only for studies whose description contains | Limits the protocol to studies whose description contains your text. |
| Apply | Arranges the open study with that protocol. |
| Delete | Deletes a saved protocol, after you confirm in the row. |
| Left button (no tool selected), Right button, Middle button, Wheel | What each mouse button and the wheel does in the image viewports. |
| Reset | Puts the mouse buttons back to the defaults. |
| Quadruped | The image uses animal direction labels (see Animal orientation labels), with its positioning view. |
| Video copy, Show original frames | Ultrasound and angiography loops play from a video copy, which is slightly compressed. Show original frames puts the original lossless frames in the same viewport, for measuring and reading. Mammograms never get a video copy. |
If something goes wrong
- "The viewer was locked after 15 minutes without activity." The images are cleared from the screen. Press Reopen study to load it again, or Back to PacsPilot.
- "The viewer could not get access to the images." Press Reopen study to try again, or Back to PacsPilot.
- "This study needs a connection. It is not saved on this device for offline use." You are offline, and this study was not opened or kept on this computer before. Press Reopen study once you are back online.
- "Your session has ended." You signed out, here or in another window. Press Back to PacsPilot and sign in again.
- "None of the requested studies can be viewed yet." The study is not prepared for viewing yet, or you cannot see it. Press Back to PacsPilot.
- "Newer images are available for this study." Press Reload to see them, or Later.
- "Different patients are open": the studies you opened together belong to different patients. Check the patient on each image before you compare.
- "Your browser blocked the viewer window." Allow pop-ups for this site, or set Viewer window to a new tab.
- "Open some series in the viewports first." Put at least one series in the layout before you save it as a protocol.
- "Give the protocol a name." or "Enter the description text to match, or untick the box.": fill in the field and press Save again.
- "Could not save. Check your connection and try again." Saving a protocol or your mouse buttons failed. The dialog stays open; press Save again.
- "Could not delete "name". Check your connection and try again." The protocol is kept. Try again.
- Save layout as hanging protocol…, My hanging protocols…, Mouse buttons… and Keyboard shortcuts… are missing from the command menu. Your viewer preferences could not be loaded. Reopen the study.
Related
- Find and open studies on the worklist
- Why is a study partly viewable?
- Write and sign a report
- Prior studies
- Use the cardiology tools
- Settings › Viewer, for how AI results show in the viewer