Vessel findings and diagram
Record vascular duplex values and findings on a vessel diagram, read the scanner's numbers from its measurement report, and copy the findings into the report.
With the Vascular and vein pack on under Settings › Specialties, each study can carry a list of vessel findings: velocities, ratios, diameters, reflux times and findings such as plaque, thrombus or occlusion, each placed on a vessel segment and side.
Open the Vessels panel
In the viewer, open the study and choose Vessels on the toolbar, or search for "Vessel findings" in the command menu. The panel opens beside the images on the diagram with the most findings, or the carotid diagram for a new study. Pick another territory from the list at the top.
Add a finding
Click a segment on the diagram, or move to it with Tab and press Enter. Pick what you measured or saw, type the value or answer, and choose Add. Segments that hold findings are filled in. Choose Save to keep the list; closing the panel with unsaved changes asks first.
Adding and saving findings needs permission to write measurements. Everyone who can view the study can see them.
Pick the exam
Pick the exam at the top of the panel, for example Carotid duplex or Venous insufficiency (reflux) study. A new study opens the exam's diagram.
Link images to a segment
Show the key image or clip frame in the viewer, pick the segment on the diagram, and choose Link image on screen. Segments with linked images show a dot. Pick the segment later to see its images; Show brings the image up when its series is on screen, and Unlink removes the link, not the image.
Read the scanner's numbers
Choose Read from scanner to place the numbers in the scanner's measurement report (DICOM SR) on their segments. PacsPilot only places a number when the report names the vessel, side and segment; anything else is listed under Not placed with the reason, and you can type it on the right segment yourself. Each report is read once, so choosing it again only adds reports that arrived since.
Preliminary impression
The sonographer types the preliminary impression under Preliminary impression and chooses Prelim done when the exam is ready for the physician. The impression is kept apart from the physician's report, and PacsPilot notes who marked it done and when. Reopen prelim lets the sonographer change it again.
Copy for the report
Copy for report puts the saved findings on the clipboard, one line per segment under a heading per territory, for example "Right ICA, proximal: PSV 125 cm/s, EDV 30 cm/s." PacsPilot records what you enter or what the scanner sent. It does not grade stenosis or suggest a category.
Updated November 7, 2026. Signed in? The same article is in the app's help panel: press
?.