Hearing results
Keep audiograms, tympanometry and other hearing tests with the patient's images, type in an audiogram from the printout, and have a second person verify it.
With the ENT pack on under Settings › Specialties, the report editor shows a Hearing results card for the patient of the study. It lists the patient's hearing tests by date: audiograms, tympanometry, acoustic reflexes, otoacoustic emissions, ABR, VNG and, in a veterinary practice, BAER hearing tests.
The audiogram chart
The newest checked audiogram is drawn with the standard symbols (ASHA 1990): circle and cross for right and left air conduction, triangle and square when masked, < and > for bone, [ and ] for masked bone. Right is red and left is blue. Up to three earlier audiograms show faded behind it, so you can see change over time.
Once a clinical reviewer has signed off the ENT pack, the card also shows the pure tone average for each ear, with the frequencies used. PacsPilot never writes a hearing loss category: the audiologist's interpretation stays with the audiologist.
Type in an audiogram
- Open the report of a study for the patient.
- In Hearing results, press Enter audiogram.
-
Type each threshold in dB HL. Add m for a masked value (
25m), type NR for no response (orNR 110for no response at 110 dB). Leave a box empty if that frequency was not tested. - Add the speech reception threshold and word recognition score if you have them, and press Save audiogram.
Enter tympanometry works the same way: the type per ear, peak pressure, compliance and ear canal volume as the device printed them.
Technologists, physicians, admins and owners can enter hearing tests. Audiologists use the technologist role or a custom role.
Verify a typed-in result
A typed-in result shows Not verified and is left out of the chart's trend until someone else checks it. The second person presses Verify, types the values again from the device printout without seeing the first entry, and presses Verify. If any value differs, PacsPilot shows which ones, and nothing is marked verified until the two entries agree. The person who typed it in cannot verify it.
Device reports
Audiometers, tympanometers and OAE or ABR systems usually print a PDF instead of sending DICOM. On the Sites page, add an ENT and audiology device export folder for the PacsPilot Agent to watch, pick the device type and write the file name rule that finds the patient and the test date. Filed reports arrive as documents on the patient's study, next to the images. Structured imports from audiometer software are added device by device once the maker's export format is confirmed.
Suggested charges
Owners and admins with charge access can ask for the audiology charges a study's date suggests
(GET /v1/studies/{uid}/ent-charges in the API). PacsPilot looks at the patient's
hearing tests performed that day, applies the bundling rules (for example, a speech test with
recognition includes the threshold) and lists the codes with notes for the coder. A typed-in
result counts only after it is verified. These are suggestions: your coder confirms every line on
the charge screen. Veterinary practices get no lines.
Moving in from another ENT system
Settings › Specialties lists the steps for moving an ENT practice to PacsPilot: the DICOM archive, the stroboscopy archive, old audiology PDFs, device report folders, and the unmatched list.
Updated November 6, 2026. Signed in? The same article is in the app's help panel: press
?.